MP920 QRG Rev1.5

S

(Global)

SW0000-1023

C

(Global)

CW00000-04095

M

(Global)

MW00000-32767

System information and status (read only)

Constant, Read only registers.

General Multi-Purpose read/write registers

Example: Flicker relays, Calendar,

*Function Block RDA: MW00000-03999

Scan time setting, error codes, ect.

Axis#1: MW100-199, Axis#2: MW200-299…

Fixed Parameters

(for each axis)

Example:

User Free: MW04000-32767

Written to in Module Configuration

Mechanical system specifications

Convention:

Define axis units, motor specs.

(pulley ratios, encoder counts per load rev)

Axis#1:MW1000-1999, Axis#2:MW2000-2999

Cannot be written by ladder

Reference: RDA Spreadsheet

Changes usually require power cycle

Reference:

* If using motion function blocks.

I (Input)

IW0000-FFFF

"Motion Monitoring"

O (Output)

OW0000-FFFF

"Motion Setting"

general purpose & motion data (Read only by application program)

general purpose &motion data (Read/Write by application program)

Physical Inputs: IW0000-7FFF

Physical Outputs: OW0000-7FFF

Convention:

IW0000-0100 for Local IO modules

Convention:

OW0000-0100 for Local IO modules

IW0100+ for M-LINK Network I/O

OW0100+ for SVB and M-LINK I/O

Axis (Motion) Input: IWC000-FFFF (for axis #1)

Axis (Motion) Output: OWC000-FFFF (for axis #1)

"motion monitoring"

Offset

40h

per axis

"motion setting"

Offset

40h

per axis

400h

per module/circuit

400h

per module/circuit

Example: IBC000 0 = axis#1 controller ready

Example:

OBC000 0 = turn axis#1 servo on

Reference:

Motion Module User Man 6.2.2

Reference:

Motion Module User Man 6.2.3

D (Local Registers)*

DW00000-16383

Used as general purpose read/write in the defined Drawing only.

Suggested

Bits: DW00000-00008

(DB000000~DB00008F)

Convention:

One-Shot

DW00009

(DB000090~DB00009F)

Word Operations:

DW00010-00025

(These can be 16-bit integers, 32-bit integers, or 32-bit F

Accumulators:

DW00026

(16-bit Integer accumulator)

DW00027

(16-bit Logic [Hexadecimal] Accumulator)

DL00028

(32-bit Long Accumulator)

DF00030

(32-bit Floating point Accumulator)

Long

DW00032-00089

Float

DW00100-00256

*Default is 32 D-registers per drawing. R-click drawing in File Manager - increase to 256 when using Function Blocks.
Reference:

#

("Sharps")

#W00000-16383

Module Configuration

Drawings:

H, L, A, I

H (High Scan)

Use for all code that runs motion related functions. 2ms is usually good.

L (Low Scan)

Use for code that runs HMI, or user operated switches, lights, etc. 20ms is usually good

A (Startup)

Use for drawings that should automatically run once at controller power up.

S (System)

MP940 only - rarely used. Scan as fast as 250us for short drawings.

I (Interrupt)

Use to run a special interrupt routine after receiving a local input defined as a dedicated "Interrupt."

MP920 Memory Map

Regi

st

er M

emory

P

ro

g

ram Memo

ry

D
E
C

I

M

A

L

H
E
X
A
D
E
C

I

M

A

L

If local registers are increased as mentioned below.

Data that end user can change without needing to
access the program.

D
E
C

I

M

A

L

Local Constants. General purpose, read-only by the specifed Drawing they
are defined in.

Set up via a table in the "properties" dialog box for each
drawing. Rarely Used

Each hardware module on the rack has several configuration files. This data is
stored in program memory.

New project requires setting Module Configuration first. Select
from File Manager under Definition Folder"