Basic Set of Registers
for Register-Based Programming
Assume Module(Circuit) #1, Axis #1. Add 400h per circuit, 40h per axis.
Motion Setting Registers (
O
Wxxxx)
Name
Word
Bit [Unit] / Note
Reference
Servo On
OBC001 0
Alarm Clear
OBC000 6
Speed ("Feed" Speed)
OLC022
[10^3 R.U./minute (by default)]
Motion Command Code
OWC020
1=Position, 3=Home, 7=Jog, 8=Step
Position Reference
OLC012
[R.U.]
Abs/Inc Position Mode
OBC001 E
0=Abs, 1=Inc
Step Distance
OLC028
[R.U.]
Direction (Step,Jog)
OBC021 2
0=Fwd, 1=Rev
Acceleration
OWC00C
[ms to rated speed (FP7)] SVB: Use
OWC020=10 to send accel to
servopack Pn80B
Deceleration
OWC00D
[ms to rated speed (FP7)] SVB: Use
OWC020=11 to send accel to
servopack Pn80E
Motion Monitoring Registers (
I
Wxxxx)
Name
Word
Bit [Unit] / Note
Reference
Servo Alarm
ILC022
=0 when no alarm. Each bit
represents different alarm
Mtn Cmd Code confirm
IWC014
Main Power On
IBC001 4
Servo On Confirm
IBC001 3
Feedback Position
ILC008