Jordan Valve Mark 17X Series Flameproof Smart Positioner User Manual

Page 12

Advertising
background image

-12-

o

peratIon

The following process will operate the valve and actuator. Prior to proceeding with any AUTO Calibration
please isolate the valve and actuator from the system.

Button Description:

Behind the access panel on the front of the positioner, there are 4 buttons. Simply back off the three Phillips head

screws slightly and rotate the cover upwards to gain access.

Run Mode (RUN):

Once power is turned on to the positioner, RUN mode will be displayed within 6 seconds on the LCD screen. RUN

indicated the positioner will adjust the valve stoke according to the input signal. There are 6 modes within RUN

cycle.

1.

RUN PV : Process Value – valve stroke %

2.

RUN SV % : Set Value – input signal 0-100%

3.

RUN SV mA : Set Value – input signal 4~20mA

4.

RUN MV : Manipulate Valve – Motor Manipulate Value (digit)

5.

RUN Vel : Velocity – Current valve stem velocity (digit)

6.

RUN Err : Error – Difference between SV and PV (%)

To cycle display modes, press “ESC” and “+” at the same time. This will cycle display modes in the order indicated

above. Alternatively pressing “ESC” and “-“ will cycle through the above modes in descending order.

Pressing “ESC” at any point will return the Mark 3400 positioner to RUN mode.

M

ark

17X S

erieS

F

laMeprooF

S

Mart

p

oSitionerS

Advertising