0 introduction – Magnum Energy Mini Magnum Panel (MMP Series) User Manual

Page 10

Advertising
background image

Page 1

©

2013 Magnum Energy, Inc.

Introduction

1.0 Introduction

Congratulations on your purchase of the Mini Magnum Panel (MMP) enclosure, part of a new line of

panel systems from Magnum Energy. Installing an inverter system is now as simple as mounting

the MMP enclosure, installing the inverter, connecting the battery bank, and if needed, bringing in

AC power from a generator or the utility. The inverter’s required AC and DC disconnects and wire

connection points are all together, and integrated in one self-contained enclosure.
This unit has been specifi cally designed to combine all of the major components required for a

renewable energy system into a single, easy to install pre-wired enclosure. This includes: inverter/

battery disconnect, AC overcurrent protection, grounding connections, and a full system inverter

bypass switch as a convenient way to isolate the inverter for battery maintenance.
Designed for single inverter applications, this enclosure features convenient front panel operation

and the optional front panel remote allows easy Magnum inverter set up, monitoring, and operation.

In addition to saving time and money with a simple and easy inverter installation, this enclosure

ensures safety and reliability by providing a UL and CSA certifi ed, code compliant system.
What makes the MMP enclosure stand out from the competition?
• It is engineered to combine the ease and cost savings of a pre-wired, factory-integrated

system with the fl exibility of a single person, fi eld installed power system.

• The self-contained enclosure system is convenient and space-saving, reducing installation time

and cost compared to a conventional approach using multiple interconnected components.

• Multiple models are available to meet the fl exibility and power demands of your application.
• Specifi cally designed to fi t Magnum inverters, but easily adaptable to connect other inverter

systems in 12, 24, or 48 VDC standardized confi gurations.

• Includes a built-in AC bypass switch with full system current capability, and a DC disconnect

breaker for safe and easy servicing of the inverter and/or battery bank.

• Additional space to install up to eight

½” (12.7mm) wide DIN rail-mounted breakers or four

1” (25.4mm) wide back-mounted breakers for use as

DC load breakers; or, space to install PV

disconnects or PV-Ground Fault Protection (PV-GFP).

• A full system capacity DC shunt (500 amps) installed to allow easy connection to a state-of-

charge battery monitor.

• AC/DC wiring connections and circuit breaker operations are easily accessible from the front.
Regulatory Compliance
The MMP has been designated as Interconnection System Equipment (ISE) and has been evaluated

by Intertek Testing Services (also known as ETL). ETL is a Nationally Recognized Testing Laboratory

(NRTL) and has listed the MMP enclosure to the following product safety standards and ratings:
Standards
• UL1741 Standard for Safety of Inverters, Converters, Controllers and Interconnection System

Equipment for Use with Distributed Energy Resources (Edition 2)

• CSA C22.2 No. 107.1, General Use Power Supplies – R2006 (Edition 3)
Ratings
• Maximum battery input: 160VDC
• Maximum PV input voltage (DC): 300VDC
• Maximum DC input short circuit current (DC): 10,000 AIC
• Operating voltage range (AC): 120-240VAC nominal
• Normal operation range: 5000 VA @25°C (MMP)

Info: NRTL’s are qualified organizations that meet Occupational Safety and Health

Administration (OSHA) regulations to perform independent safety testing and product

certification.

Advertising