E-31

Troubleshooting

En

gl

is

h

Check the “Projector Troubleshooting” section in the User’s Guide (UsersGuide_English.pdf) on
the bundled CD-ROM whenever you experience any problem with the projector.

POWER

TEMP

Alert

: Amber flashing

J

Red steady

: Red flashing

(1-second interval)

:

Power has turned off automatically due to internal overheating.
Perform the following steps.

1

After confirming that the POWER/STANDBY indicator is lit
red, unplug the AC power cord and wait for about 60
minutes to allow the projector to cool down.

2

Check for any blocking of the projector’s intake vents and
exhaust vents, and make sure that there is sufficient space
around the projector.

) “Setup Precautions” (page E-15).

3

Clean dust accumulated around the projector’s intake vents
and exhaust vents.

) See “Cleaning the Projector” section in the User’s Guide

(UsersGuide_English.pdf) on the bundled CD-ROM.

4

Plug the AC power cord back in, and turn on the projector
again.

POWER

TEMP

LAMP

Alert

: Amber flashing

J

Red steady

: Red flashing

(0.5-second interval)

: Red flashing

(0.5-second interval)

:

Power has turned off automatically due to a lamp problem.
After confirming that the POWER/STANDBY indicator is lit red,
unplug the AC power cord, then plug it back in and turn on
the projector again. If this does not correct the problem, wait
for the projector to cool down and then check the lamp
cartridge for damage. If there is nothing wrong with the lamp
cartridge, take it to your original dealer or authorized CASIO
Service Center.

POWER

TEMP
Alert

: Amber flashing

J

Red steady

: Amber flashing
:

Power has turned off automatically because the lamp cover is
open. Perform the following steps.

1

After confirming that the POWER/STANDBY indicator is lit
red, unplug the AC power cord and wait for about
60 minutes to allow the projector to cool down.

2

Close the lamp cover.

) “To replace the lamp” (page E-27).

3

Plug the AC power cord back in, and turn on the projector
again.

POWER

TEMP

Alert

: Amber flashing

J

Red steady

: Red flashing

(2-second interval)

:

Internal memory error.
After confirming that the POWER/STANDBY indicator is lit red,
unplug the AC power cord, wait for about 60 minutes to allow
the projector to cool down, and then take it to your original
dealer or authorized CASIO Service Center.

POWER
LAMP

Alert

: Green steady
: Red flashing

(1-second interval)

:

U

It is time to replace the lamp. Replace the lamp following the
steps under “Replacing the Lamp” on page E-27.

POWER

LAMP
Alert

: Amber flashing

J

Red steady

: Red steady
:

The allowable life for the lamp has been exceeded, and the
projector will not turn on. Replace the lamp following the steps
under “Replacing the Lamp” on page E-27.

Projector Troubleshooting

Indicator/Alert

Description

Advertising