Command/response table for sis commands (cont’d), Names, If a preset is unassigned, then – Extron Electronics MAV Plus Series User Manual

Page 118: Prst, I/o grouping

Advertising
background image

4-11

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

Command/response table for SIS commands (Cont’d)

Command

ASCII Command Response

Additional description

(host to switcher)

(switcher to host)

Names

Write global preset name

Esc X11

,

X19

NG

Nmg

X11

,

X19

Example:

Esc

1,Security 1NG

Nmg01,Security 1

Name global preset 1 “Security 1”.

Read global preset name

Esc X11

NG

X19

Example:

Esc

2NG

Security 2

Write room name

Esc

X8

,

X19

NR

Nmr

X8

,

X19

Example:

Esc

1,Classrm 1NR

Nmr01,Classrm 1

Name room “Classrm 1”.

Read room name

Esc

X8

NR

X19

Write room preset name

Esc

X8

*

X12

,

X19

NP

Nmp

X8

*

X12

,

X19

Example:

Esc

1*3,Podium_DVDNP

Name room 1, preset 3

Nmp01*03,

X19

“Podium_DVD”.

Read room preset name

Esc

X8

*

X12

NP

X19

If a preset is unassigned, then

X19

displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset

X11

.

If a room preset is saved, but not yet named, the default name is Rm

X8

Prst

X12

.

Write input name

Esc

X1

,

X19

NI

Nmi

X1

,

X19

Example:

Esc

1,Podium camNI

Nmi01,Podium cam

Name input 1 “Podium cam”.

Read input name

Esc

X1

NI

X19

Write output name

Esc

X1

,

X19

NO

Nmo

X1

,

X19

Example:

Esc

1,Main PJ1NO

Nmo01,Main PJ1

Name output 1 “Main PJ1”.

Read output name

Esc

X1

NO

X19

I/O Grouping

Write input grouping

Esc X10

1

X10

2

X10

n

I

Gri

X10

1

X10

2

X10

3

X10

n

Each

X10

entry is the group

number assigned to an input
position, starting from input 1,
n is the maximum number of
inputs for this model.

Example for CrossPoint 450 Plus 3232:

Esc

I40…33I

See below

01

Input:

Gri

Response #s = group:

Input 1 in group 4

02 03 04 05 06 07 08 09 10 11 12

4 0 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3

13 14 15 16 17 18 19 20 21 22 23 24

Input 2 not grouped

2 1 2 2 3 3 3 3

25 26 27 28 29 30 31 32

Input 32 in group 3

Input 1 - Group 4, Input 2 - Group
0 (not grouped),…Input 31 -
Group 3, Input 32 - Group 3.

Write output grouping

Esc X10

1

X10

2

X10

n

O

Each

X10

entry is the group

Gro

X10

1

X10

2

X10

n

number assigned to an output
position, starting from output 1,
n is the maximum number of
outputs for this model.

Read input grouping

Esc

I

X10

1

X10

2

X10

3

X10

n

One

X10

entry for each input,

starting from input 1, n is the
maximum number of inputs for
this model.

Example for CrossPoint 450 Plus 2424:

Esc

I

See below

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08 09 10 11 12

1 1 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3

13 14 15 16 17 18 19 20 21 22 23 24

Input 9 not grouped

Input 24 in group 3

Advertising