Operation, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Operation

3-14

4

.

Press and release the output 1 button (figure 3-14).

1

2

3

4

5

6

7

8 15 16

17 18 19 20 21 22 23 24 31 32

O
U

T
P

U

T
S

Press and release the Output 1 button.
The button blinks green to indicate that only the selected RGBHV
or video input will be tied to this output.

The Enter button blinks
green to indicate the need to
confirm the change.

C O N T R O L

PRESET

ENTER

ESC

VIEW

Figure 3-14 — Select the output

5

.

Press and release the Enter button (figure 3-15).

ENTER

All input buttons and output buttons
return to unlit or background illumination.

Press the Enter button to
confirm the configuration
change.

The Enter button returns to
unlit or background
illumination.

Figure 3-15 — Press the Enter button

The current configuration (figure 3-16) is now:

Input 5 video tied to output 1, output 3, output 4, and output 8

Input 5 audio tied to output 3, output 4, and output 8

Input 5 video tied

to outputs 1, 3, 4, and 8.

Input 5 audio tied

to outputs 3, 4, and 8.

Input

Output

1

3
4

8

5

Video
Audio

Figure 3-16 — Example 2, final configuration