Operation, cont’d – Extron Electronics MAV Plus Series User Manual

Page 73

Advertising
background image

Operation, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Operation

3-30

2

.

Press and hold the Preset button for approximately 2 seconds until it blinks
(figure 3-44).

PRESET

PRESET

1

2

3

4 15 16

17 18 19 20 31 32

I

N
P
U

T
S

Press and hold the Preset button until it blinks.

2 seconds

All input buttons with assigned
presets light red.
If you then save the configuration
to a lit preset number, the configuration
data at that preset location
will be overwritten
.

Red

(Preset Assigned)

Unlit

(No Preset Assigned)

Figure 3-44 — Enter Save Preset mode

3

.

Press and release the input or output button for the desired preset
(figure 3-45).

1

2

3

4

5

6

7

8 15 16

17 18 19 20 21 22 23 24 31 32

I

N
P
U

T
S

C O N T R O L

PRESET

ENTER

ESC

VIEW

The Enter button blinks to

indicate the need to save
the preset.

The Preset button
continues to blink.

Press and release the Input 1 button.

The button blinks red to indicate that this preset
number is selected but not saved.

Figure 3-45 — Select the preset

Figure 3-42 on page 3-29 shows the presets associated with the various input
and output buttons for all three front panel configurations.

4

.

Press and release the Enter button (figure 3-46). The current configuration is
now stored in the selected memory location.

C O N T R O L

PRESET

ENTER

ESC

VIEW

The Enter and Preset
buttons return to unlit or
background illumination.

Press the Enter button to
save the preset.

All input buttons return to unlit
or background illumination.

Figure 3-46 — Press the Enter button

Advertising