background image

characters, counts from the transmitting head

12 1

End

sign 03H

44 bytes in total
Transmitting the accumulated weight by using the format below:

Sect Length

(byte) Definition

Descrition

1 1

Beginning

sign

02H

2 1

Transmitting

head

A~Z, representing indicator address

3 4

Sign

“SUM=”

4

11

Weight

ASCII character string

5 3

Unit

space

+

t/kg/g/mg

6 1

Enter

key

0DH

7

2

Verifying sum

1 byte (in hex) verifying sum in 2 bytes ASCII
characters, counting from the transmitting head

8 1

End

sign 03H

24 bytes in total
3. Indicator communicating parameter setting:
1).

Communicating

parameter

Consisting

of

communicating

address

(parameter P21), baud rate (parameter P19) and

communicating mode (parameter P20).

2). Parameter Setting

Refer to Keys Function chapter for setting methods

8. Scoreboard Connection

! The down-lead of scoreboard must be connected to the scoreboard accurately. If be

connected in wrong way, damages will happen to the output port of indicator and the input

port of scoreboard, and sometimes damage will happen to the indicator and the scoreboard.

Special wire is required in connection.

1. The interface of the scoreboard adopts the 15-pin RS232 plug (using the same socket with the
COM port). Refer to 9 and 10 pin in Figure 6 for down-lead definition:

2. The 20mA current loop signals or RS232 signals is supposed to be the signals of scoreboard and
are serially transmitted by means of binary coded character with baud rate as 600. Each frame of
datum has 11 bits: 1 start bit (0), 8 data bits (low bit in front), 1 sign bit and 1 stop bit.

3. One set of datum is transmitted once every 200ms and each set of datum consists of 3 frame
datum.
The first frame:
1

0
bit 0 1 2 3 4 5 6 7 8 9 10
d0 d1 d2 d3 d4 d5 d6 d7
start sign stop
bit X Y G18 G16 G17 bit bit

(图 6.1 ) The first frame view

The second frame: