Epson XK3190-H2B User Manual

Page 14

Advertising
background image

press. Press <<Exit>>or <<Enter>> to return to weighing mode. If a programmable data
needs to be modified, press keys in the order of <<Modify>><<Figures>><<Enter>> to
enter new data. Data order is displayed as follows:

Pressing times Reminding symbols

Data meaning

1 YXX printing is not allowed in weighing mode of

division=0.1e

2 A/D Weight A/D internal code
3 P09 Display the weight in zero point
4 P10 Display zero point upon powered on
5 P11 Calibrate zero point internal code
6 F Full Scale
7 E Check division 0.01~50, 12 options in total
8 P14 Displaying ratio
9 P15 Displaying Non-linearity edited value within

the scope of –1%Max~1%Max, weight unit

10 P16 Initial zeroing range 2~100 unit: %Max.

This parameter determined the difference
between present load and calibrated zero
point with 20%Max as default in first
zero-setting upon powered on.

11 P17

Zero-tracing switch, 0 is off and 1 is on

12 P18

Weight unit:

0=t

1=kg

2=g 3=mg

13 P19

bit number

0=600 1=1200 2=2400 3=4800 4=9600BPS

14 P20

Communication mode:

0= constant sending 1= answer style

15 P21 Communication address:

1~255

16 P22 Printer styles:

0=without Chinese characters database
1=with Chinese characters database (only
the printer with Chinese characters
database is applicable at present, this para.
does not work)

17 P23 The lighting time of the background light

1~255, unit: Second. 0=no automatic off

18 P24 Scoreboard switch:

0=on 1=off

19 P25 RS232 switch

0= on 1=off

20 P26

Displaying divisions 0.01~50 12 options

total

21

P27

Displaying Version No. For example: H2C

Advertising