Data printing format, Weight list – Epson XK3190-H2B User Manual

Page 16

Advertising
background image

Press keys in the order of <<Verify>>…<<Verify>>, <<modify>>, <<Figure>> and

<<Enter>> to enter or edit a calibrated data.

(Initializing) zeroing scopes (P16 or P30) can be achieved by using above-mentioned

method only, with 2-100(%Max) as valid value scope. Non-linearity tolerance is the
difference between zero point and 50%F.S after the full scale is calibrated.
Non-linearity edited value (15) is the negative of non-linearity tolerance.

26 <<Type>><<Figure>> Set new category number. After press <<Type>>, the category

cursor twinkles.

27 <<Type Cancel>> Category number and weighing serial number disappear and then

accumulation and data saving can not be executed.

28 <<COMM >> switch of the communication function to the upper computer. Marked by

COMM

29 <<Accum>> Record and accumulate the present weight, then go to accumulation

display mode.

30 <<Memo recall>>Display the accumulated weight of the present category. Accumulated

value is marked by SUM.

31 <<Memo clear>> Clear the weight record of the present category and the accumulated

weight, and then return to weighing mode. It only works in accumulation state.

32 << Memo recall>> <<Total clear>>Clear all weighing records and accumulated value.
33 <<COMM>><<memo recall>><<Mode Tranl>>Transfer the weight list to upper

computer.

Data Printing Format

1. Micro-printer printing format

a) Heading printing format







b) Data printing format

State

Data format

Net weight

NYZZXXXXXXXX kg

Gross weight

GYZZXXXXXXXX kg

Tare

PZL XXXXXXXX kg

Weight limit

XZL XXXXXXXX kg

Accumulation

……………………………..
SUM XXXXXXXX kg

Date & time

XX year XX month XX day XX hour XX minute

Weight A/D inner code

A/D XXXXXXXX

Parameter YY

PYY XXXXXXXX

Weight list

Xk3190-

H2B 1.02

16:39 15th Oct. 2003

Serial No. Weight Unit

Advertising