1. Model

XK3190-H2B

2. Accuracy

Meets the regulations of OIML, R76, JJG-555
and national standard of the electronic crane
scale. Accuracy - Class Ⅲ

Division

From 0.01 to 50, 12 options in total. Verifying
division will be set automatically each time when
powered on. Usually, the division is supposed
not to be modified.

Units of Measure

4 options: t, kg, g and mg

3. Analogue
Conversion Principle

24 bit ∑-△ mode, A/D converter

Input Signal Range

-2mV~+18mV

Max Net Input Signal

20mV

Conversion Rate

6.25 times per second

A/D Conversion Resolution

500,000

Non-linearity <0.01%F.S
F.S. Temperature Coefficient

<6PPM/℃

Calibration

Full

digital

calibration

(FDC)

Load Cell Excitation DC

5V

Load Cell Drive Capacity

up to 4 load cells at 350Ω

Connecting Method of Load Cell

4 leads

Displaying Cycle

160ms

4. Clock

Displaying Y/M/D, H/M/S and leap year/month

Accuracy

±

5s/24h, free from influence of powering off

5. Keypad
Digital Keys

0~9, ·, -

Function Keys

24 (12 overlapped with digital keys)

Key Material Sealed elastomer
6. Scoreboard Interface

Serial output mode

Transmission Mode

20mA current loop

Data Type

11 bits

Baud Rate

600

Transmission Distance

2000m

7. Serial Communication Interface
Transmission Mode

RS232C/RS422 (Optional)

Baud Rate

600, 1200, 2400, 4800, 9600

Transmitted data format

10 bit:1 start bit, 8 data bits (ASCⅡ Code), 1

stop bit

Transmission Distance

RS232:≤30m

RS422:≤1200m

8. Printer Port

Standard parallel output port

9.

Data

Storage

11 categories of weight records, net/gross