1
02H(XON) begin
2 A~Z address serial number
A~B order A: Handshaking
order B: Read the displayed weight
3
4
Transmitting the corresponding data according to the instruction
…
Transmitting the corresponding data according to the instruction
n-1
Transmitting the corresponding data according to the instruction
n
Transmitting the corresponding data according to the instruction
n+1
XOR verifying high 4 bits
n+2
XOR verifying low 4 bits
n+3
03H (X0FF) end
XOR=2 ⊕ 3 ⊕…(n-1) ⊕ n
Hereunder is the content of 4~n during indicator transmitting:
Order A
No data
Each frame is composed of 6 sets of dutum
Order B
Present weight, format:
Each frame is composed of 16 sets of dutum
a: sign (+ or -)
b: weight value(8 bits)
: (from up to down)
g
h: decimal digits from
right to left (0~4)
Remarks: high/low 4 bits confirmation via XOR verifying: If XOR and high/low 4 bit ≤9, add 30h
to become ASCⅡ, and then sent out. For example: When XOR verifying high 4 bits=6, add 30h,
then become 6 in ASCⅡ and sent out. If XOR and high/low 4 bits ≥9, add 9, then become ASCⅡ
to be sent out. For example: When XOR verifying high 4 bits=B, add 37h, then become 42h, i.e.,
B of ASCⅡ to be sent out.
3). Mode transmitting
During weighing mode, press <<Comm.>> <<Accumulation Display>><<Mode
Transmitting>> key to transmit the weight data list of the present category. Every batch weight
data is transmitted first through the format below:
Sect
Length (byte)
Definition
Description
1 1
Beginning
sign
02H
2 1
Transmitting
head
A~Z, representing indicator address
3
1
Gross/net weight
net weight= “N”/gross weight = “G”
4
4
Category//number
xxx + Space key
6 11
Date
2004y04m05d
7 9
Time
08h15m20s
8
10
Weight
ASCII character string
9 3
Unit
space
+
t/kg/g/mg
10 1
Enter
key 0DH
11
2
Verifying sum
1 byte (in hex) verifying sum in 2 bytes ASCII