background image

accurately. If connected in wrong way, the output port of the indicator or the input port of

computer communication will be damaged, and sometimes the damage will happen to the

indicator, computer and peripherals.

! Special computer operation skills and programming ability is required for computer

communication operation, which shall be performed and directed by qualified service

personnel only. Non-professionals are supposed to be out of connection operation.

1. The communication port adopts the 15-pin plug (jointly used with the scoreboard). Pins

layout and definition is shown in Figure 6: 6,7,8 (RS232) , and, 1,2,3,4(RS422/485)

2. All datum are ASCII and each set is composed of 10 bits:1 start bit, 2-9 data bit, 10 stop

bit.

Communicating methods are classified as follows:

1). In Sequence:

The data transmitted is the present weight displayed (gross or net), each frame of datum is

composed of 14 sets of datum. Hereunder is the format:

Byte Serial Number

Descriptions

1

02H(XON) begin

2

+ or - symbol bit

3

Weighing data high bit

Weighing data …

Weighing data …

10

Weighing data low bit

11

Decimal from right to left (0~4)

12

XOR verifying high 4 bits

13

XOR verifying low 4 bits

14

03H(X0FF) end

XOR=2 ⊕ 3 ⊕ 4 …8 ⊕ 9

2). Instruction method
The indicator transmits the corresponding data according to the instruction of upper computer.
One frame of datum will be transmitted every time when upper computer send one
instruction. Hereunder is the instruction transmitted:

Byte Serial Number

Descriptions

1

02H(XON) begin

2 A~Z address serial number

A~B order A: Handshaking
Order B: Read the displayed weight

3

4

XOR verifying high 4 bits

5

XOR verifying low 4 bits

6

03H (X0FF) end

XOR= 2 ⊕ 3

The output content of indicator:

Byte Serial Number

Descriptions

Advertising