can be printed when outside of weighing mode. The present weight can not be printed if
unsteady, but it can be printed after resuming steady (the data is supposed to be steady

only after the unit of measure displayed). Reprinting can not be performed within 5
seconds after each printing. While power is low, printing can not be performed, or
abnormal printing will appear. Printing format can be referred to in Chapter 4. Minus

weight value can not be accumulated and recorded.

9. << Paper roll >> Keep printer conveying printing paper until releasing this key. It does

not work to external printer.

10. <<Shift>><<Mark PR>> Print weighing report heading.

11. <<Memo recall>><<Shift>><<List PR>> Print weight record and accumulated value of

the present category, available in accumulation function state.

12. <<Entert>>(<<Weigh>>) Check the validity of the data inputted just now and save it,

then return to weighing mode. If no data entered, return to weighing mode directly.

13. <<TIME>>Display present date

rq XX-XX-XX

Press again, Current time appear

SJ XX-XX-XX

Press <<Weigh>> to quit

14. <<Time>> (<<Time>>)<<Modify>><<Figure>><<Enter>> Edit date or time, and

decimal point serves as dividing symbol of year and date; hour, minute and second. The
internal real-time clock will not work if time was not set after battery installation.

15. <<Minus WT>> Go to minus weighing mode, the instrument identifying mark becomes

F and weight displayed become 0 at the same time. The weight of the object taken off from
the scale will be displayed then. Press<<Minus Weight>> to quit the minus weighing
mode.

16. <<Shift>><<Delete>> Delete the last weighing record of present category in

accumulation state. Delete the last figure entered in entering state. Return to weighing
mode when no figure entered.

17 <<Exit>> Return to weighing mode.

18 <<WT limit set>> Display present weighing limit. The weighing limit is set to be +9e

upon powered on. The displayed figure is

HZL XXXXX kg
Press <<Weigh>> key to quit.

19 <<Shift>><<WT limit set>><<Figure>><<Enter>> Set weighing limit and the limit is

not supposed to be above maximum weight to be weighed.

20 <<Tare>>Check the present tare and the figure is displayed as follows:

PZL XXXXXkg

Press <<Weigh>> to quit

21. <<Shift>><< Tare Preset >><<Figure>><<Enter>> Preset tare.

22. <<Background Light>> LCD background light on/off key, the light time is decided by

the parameter P23

23. <<Shift>><<Contrast bright>><<Figure>><<Enter>> Set contrast within the scope

(0-15), the weakest is 0 and the brightest is 15

24 <<Verify>> Check every data in the instrument and next data will displayed after each