Sealey TA065 User Manual

Ta065, Lux meter, Instructions for

Advertising
background image

InstructIons for:

LUX METER

MoDEL no :

TA065

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATION

1.1.

GENERAL SAFETY

familiarise yourself with the applications, limitations, and potential hazards of the lux meter.

Keep the lux meter clean and in good condition.

If using to assess bright lights, apply common sense regarding eye protection.

DO NOT operate the meter in a flammable or explosive atmosphere.

DO NOT get the lux meter wet or use in damp or wet locations or areas where there is condensation.

DO NOT use the lux meter for any purpose other than that for which it is designed.

DO NOT allow untrained persons to operate the lux meter.

DO NOT operate the lux meter when you are tired or under the influence of alcohol, drugs or intoxicating medication.

WARNING: The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions

and situations that may occur. It must be understood that common sense and caution are factors which cannot be built into this

product, but must be applied by the operator.

High precision portable light meter with silicon photodiode and filter. Includes a large back-lit LcD screen that displays in either lux or

fc. Ideal for general use or ensuring sufficient lighting in workshop or office environments. features Max./Min., data hold, auto power off

and calibration procedure. supplied in storage case with 9V battery.

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TA065

range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-99999 lux /0-9999fc

Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±6%

sample rate: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 times per second

Battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 x 9V (supplied)

Original Language Version

tA065 Issue: 1 - 19/02/14

fig.1

1 . . . Light sensor

2 . . . LcD Display

3 . . . on/off Key

4 . . . Hold Key

5 . . . Lux selector Key

6 . . . Max/Min Key

7 . . . fc selectorKey

8 . . . Backlight Key

9 . . . Light sensor cap