Pro-flo efi installation instructions, Power on enter/exit, Up / down – Edelbrock 3530 User Manual

Page 30: Up down up down, Up down, Calibra tion module diagram exit exit

Advertising
background image

30

Pro-Flo EFI Installation Instructions

©2005 Edelbrock Corporation
Rev. 2/05

Brochure #63-0273

Catalog #3530 & #3531

FUEL @ ____ 2000:

±0%

EXIT = scroll ENTER

POWER ON

ENTER/EXIT

UP

DOWN

UP

DOWN

UP

DOWN

UP / DOWN

UP / DOWN

ENTER/EXIT

ENTER/EXIT

UP / DOWN

ENTER/EXIT

SAVE

RESTORE

EXIT

EXIT

UP / DOWN

WEBER/ EDELBROCK

Pro-Flo EFI System

(1-2 second commercial )

RPM: 3000 FUEL: 4.0 ms

VAC: 12.0Hg SPK: 36

˚

TH20: 180

˚

F TPS: 28

˚

TAIR: 98

˚

F Volt: 14.5

Idle: 25% RPM: 3000

TPS: 28

˚

Target:

950

RPM: 3000 –> •••••••••

VAC: 12.0 –> ••••

(software identification)

ECU: Q1.3 (c) WEBER ’93f

CAL: EDEL xxxx CM: 1.6

< FUEL MODIFIERS >

ENTER to select

< SPARK MODIFIERS >

ENTER to select

FUEL @ WOT 1000:

±0%

EXIT = scroll ENTER

FUEL @ 06" 1000:

± 0%

EXIT = scroll ENTER

FUEL @ 12" 1000:

± 0%

EXIT = scroll ENTER

FUEL @ 18" 1000:

± 0%

EXIT = scroll ENTER

Transient Fuel:

± 0%

EXIT = scroll ENTER

Cold Start Fuel:

± 0%

EXIT = scroll ENTER

Global Fuel Mod:

± 0%

EXIT = scroll ENTER

FUEL @ ____ 1000:

±0%

EXIT = scroll ENTER

FUEL @ ____ 3000:

± 0%

EXIT = scroll ENTER

FUEL @ ____ 4000:

± 0%

EXIT = scroll ENTER

FUEL @ ____ 5000:

± 0%

EXIT = scroll ENTER

FUEL @ ____ 7000:

± 0%

EXIT = scroll ENTER

SPRK @ WOT 1000:

±0

˚

EXIT = (+) = (

-

)

SPRK @ 9" 1000:

± 0

˚

EXIT = (+) = (

-

)

SPRK @ 18" 1000:

± 0

˚

EXIT = (+) =(

-

)

SPRK @ ____ 1000:

±0

˚

EXIT = scroll ENTER

SPRK @ ____ 1750:

±0

˚

EXIT = scroll ENTER

SPRK @ ____ 2500:

±0

˚

EXIT = scroll ENTER

SPRK @ ____ 3500:

± 0

˚

EXIT = scroll ENTER

SPRK @ ____ 4500:

± 0

˚

EXIT = scroll ENTER

SPRK @ ____ 6000:

± 0

˚

EXIT = scroll ENTER

Global SPRK Mod:

± 0

˚

EXIT = scroll ENTER

UP

DOWN

UP

DOWN

ENTER

EXIT

UP

DOWN

ENTER

EXIT

UP

DOWN

Target Idle RPM: 950

EXIT = scroll ENTER

Idle Fuel Mod:

± 0%

EXIT = (+) = ( - )

UP

DOWN

Idle Spark Mod:

± 0

˚

EXIT = scroll ENTER

Idle Spd Actvty:

± 0%

EXIT = (+) = ( - )

Rev limiter RPM: 6750

EXIT = scroll ENTER

Base Ti m’g set: OFF

EXIT = scroll ENTER

Closed loop fuel: OFF

EXIT = scroll ENTER

Idle Control: OFF

EXIT = scroll ENTER

SAVE data set: A/B/C

EXIT = scroll ENTER

RESTORE: baseA/B/C

EXIT = scroll ENTER

Saving In progress…

Saved to data set #A

Press EXIT

Restore In progress…

Data set #A RESTORED

Press EXIT

(Return to main menu)

< MISC. MODIFIERS>

ENTER to select

(FROM ANYWHERE IN MENU)

(NOTICE: Some values shown represent arbitrary examples)
(DIAGNOSTIC error messages will flash on any screen)

CALIBRA

TION MODULE DIAGRAM

EXIT

EXIT

Advertising
This manual is related to the following products: