Important warning! installation and wiring, Operation, Page 2 – Whelen M4A User Manual

Page 2: Set 3 set 1 set 4 set 2

Advertising
background image

Page 2

To +VBAT

M4

Lighthead

(2-Wire)

LED Color
BLACK

MOUNTING DIMENSIONS

4.20"

2.10"

0.25"

0.625"

0.25"

WIRING DIAGRAM

To +12V

To +12V

To +12V

WHT/VIO

LED Color

BLACK

VIOLET

GREY

SYNC

Ground

Ground

1A Fuse

1A Fuse

3A Fuse

3A Fuse

SP/ST

SP/ST

SP/ST

MOM. SW

M4

Lighthead

(5-Wire)

M

O

U

N

T

I

N

G

S

U

R

F

A

C

E

Gasket-

Use formed gasket on

flat, smooth surfaces

only.

#8 x 1"

PPHSMS

M4 Assembly

Slotted Hole
Screw Grommet

Set 3

Set 1

Set 4

Set 2

Sequences

Operation of LED sets

Solid

T

Left to Right

op to Bottom

Diagonal

All On

All Off

1 - 3

2 - 4

1 - 2

3 - 4

1 - 4

2 - 3

Alternates with

Alternates with

Alternates with

Alternates with

M4 Sequencing & Phasing: The M4
lighthead has 4 sets of 3 LEDs. These sets
cycle through the 4 sequences shown.

Pattern

Seq. Phase

1

SignalAlert™

Solid

PH.1

2

SignalAlert™

Solid

PH.2

3

SignalAlert™

L/R

PH.1

4

SignalAlert™

L/R

PH.2

5

SignalAlert™

T/B

PH.1

6

SignalAlert™

T/B

PH.2

7

SignalAlert™

Diag

PH.1

8

SignalAlert™

Diag

PH.2

17 DoubleFlash 75 Solid

PH.1

18 DoubleFlash 75 Solid

PH.2

19 DoubleFlash 75 L/R

PH.1

20 DoubleFlash 75 L/R

PH.2

21 DoubleFlash 75 T/B

PH.1

22 DoubleFlash 75 T/B

PH.2

23 DoubleFlash 75 Diag

PH.1

24 DoubleFlash 75 Diag

PH.2

25 SingleFlash 75

Solid

PH.1

26 SingleFlash 75

Solid

PH.2

27 SingleFlash 75

L/R

PH.1

28 SingleFlash 75

L/R

PH.2

29 SingleFlash 75

T/B

PH.1

30 SingleFlash 75

T/B

PH.2

31 SingleFlash 75

Diag

PH.1

32 SingleFlash 75

Diag

PH.2

9

CometFlash®75 Solid

PH.1

10 CometFlash®75 Solid

PH.2

11 CometFlash®75 L/R

PH.1

12 CometFlash®75 L/R

PH.2

13 CometFlash®75 T/B

PH.1

14 CometFlash®75 T/B

PH.2

15 CometFlash®75 Diag

PH.1

16 CometFlash®75 Diag

PH.2

33 ComAlert™

Solid

PH.1

34 ComAlert™

Solid

PH.2

35 ComAlert™

L/R

PH.1

36 ComAlert™

L/R

PH.2

37 ComAlert™

T/B

PH.1

38 ComAlert™

T/B

PH.2

39 ComAlert™

Diag

PH.1

40 ComAlert™

Diag

PH.2

41 LongBurst™

Solid

PH.1

42 LongBurst™

Solid

PH.2

43 LongBurst™

L/R

PH.1

44

LongBurst™

L/R

PH.2

45

LongBurst™

T/B

PH.1

46

LongBurst™

T/B

PH.2

47

LongBurst™

Diag

PH.1

48

LongBurst™

Diag

PH.2

49

PingPong™

Solid PH.1

50

PingPong™

Solid PH.2

51

PingPong™

L/R

PH.1

52

PingPong™

L/R

PH.2

53

PingPong™

T/B

PH.1

54

PingPong™

T/B

PH.2

55

PingPong™

Diag

PH.1

56

PingPong™

Diag

PH.2

58

SingleFlash 60

L/R

59

SingleFlash 60

T/B

60

SingleFlash 60

Diag

61

SingleFlash 90

Solid

62

SingleFlash 90

L/R

63

SingleFlash 90

T/B

64

SingleFlash 90

Diag

65

SingleFlash 120 Solid

66

SingleFlash 120 L/R

67

SingleFlash 120 T/B

68

SingleFlash 120 Diag

69

SingleFlash 300

Solid

70

SingleFlash 300

L/R

71

SingleFlash 300

T/B

72

SingleFlash 300

Diag

73

DoubleFlash 150 Solid

74

DoubleFlash 150 L/R

75

DoubleFlash 150 T/B

76

DoubleFlash 150 Diag

77

ComAlert™ 150

Solid

78

ComAlert™ 150

L/R

79

ComAlert™ 150

T/B

80

ComAlert™ 150

Diag

81

ActionFlash™50

Solid

82

ActionFlash™50

L/R

83

ActionFlash™50

T/B

84

ActionFlash™50

Diag

85

ActionFlash™150 Solid

86

ActionFlash™150 L/R

57

SingleFlash 60

Solid

87

ActionFlash™150

T/B

88

ActionFlash™150

Diag

89

ModuFlash™

Solid

90

ModuFlash™

L/R

91

ModuFlash™

T/B

92

ModuFlash™

Diag

117 PinWheel SLOW
118 PinWheel MEDIUM
119 PinWheel FAST
120 PinWheel VARIABLE
121 PinWheel MEDIUM w/Solid

123 ActionScan™

124 SignalAlert™ Steady

93

DoubleFlash 120

Solid

94

DoubleFlash 120

L/R

95

DoubleFlash 120

T/B

96

DoubleFlash 120

Diag

97

PingPong™120

Solid

98

PingPong™120

L/R

99

PingPong™120

T/B

100 PingPong™120

Diag

101 TripleFlash™75

Solid

102 TripleFlash™75

L/R

103 TripleFlash™75

T/B

104 TripleFlash™75

Diag

105 TripleFlash™120

Solid

106 TripleFlash™120

L/R

107 TripleFlash™120

T/B

108 TripleFlash™120

Diag

109 Action SF 60/120

Solid

110 Action SF 60/120

L/R

111 Action SF 60/120

T/B

112 Action SF 60/120

Diag

113 Action SF 60/TF 120 Solid
114 Action SF 60/TF 120 L/R
115 Action SF 60/TF 120 T/B
116 Action SF 60/TF 120 Diag

122 CalScan

*
*125 Steady

*No low power for this pattern.

ITALIC

= SYNC

BOLD = Cal Title XIII Compliant

.

L/R=Left/Right

T/B=Top/Bottom

CAUTION! DO NOT LOOK DIRECTLY AT THESE LEDS WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

IMPORTANT WARNING!

Installation and Wiring:

External Flasher Models: This product draws significantly less current than
a standard incandescent automotive bulb. If your flasher does not operate
properly, it may be necessary to replace your flasher module with a
Whelen® flasher module. Contact your sales representative for application.
Caution: Permanent mounting of this product will require drilling. It is
absolutely necessary to make sure that no other vehicle components
could be damaged by this process. Check both sides of the mounting
surface before starting. If damage is likely, select a different location.
WARNING! All customer supplied wires that connect to the positive
terminal of the battery must be sized to supply at least 125% of the
maximum operating current and FUSED at the battery to carry that
load. DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!
NOTE: The color of the Positive Wire is determined by the color of the
LED. In this manual, RED is used as a reference color.
1.

Using the dimensions shown, mark the 2 mounting hole locations and
wire access hole location onto the mounting surface.

2.

Drill the two, 0.250” diameter mounting holes and a 0.625” (minimum)
wire access hole into the mounting surface.

3.

Place the gasket into position on the rear of the M4 assembly. Insert
the slotted hole screw grommet through the mounting holes on the M4/
Gasket assembly.

4.

Feed the M4 wires through the wire access hole in the mounting
surface. Press the M4/Gasket/Grommet assembly onto its mounting
location so that it is flat against the mounting surface. With the
assembly in position and using the hardware provided, tighten the
mounting screws until the lighthead assembly is drawn firmly against
the mounting surface. DO NOT OVERTIGHTEN!

5.

Using appropriately sized wires (minimum 18 AWG), extend the M4
wires to their designated connections. Refer to the diagram below for
wiring and fusing information.

Operation:

Flash Mode / RED:
Apply +VBAT to the RED wire to activate the lighthead in “flash mode”.
In flash mode, you may change the flash pattern using Scan-Lock™.
Low Power / VIOLET:
The type of switch used depends on how the operator wishes the Low
Power feature to function:
Latching Mode:
By applying +VBAT to the VIO wire for less than 1 sec., the
lighthead is “latched” into low power. The unit must be turned off and then
back on to restore normal operation. (A momentary switch is preferred)
Level Mode: Applying +VBAT to the VIO wire for more than 1 sec. holds the
lighthead in low power mode until voltage is removed.
(A toggle switch is preferred)

SYNC / GREY
To SYNC two lightheads, configure both lightheads to display the same
Phase 1 (Simultaneous) pattern. Turn the power off and connect the GREY
wire from each lighthead together. When the lightheads are activated their
patterns will be synchronized. To configure two lightheads to alternate their
patterns, advance the pattern of either lighthead to Phase 2 (Alternating) of
the current pattern.
NOTE: You can also program the 2 banks of LEDs inside the lighthead
to flash in different configurations (See M4 Sequencing and Phasing).
Scan-Lock™ / WHT/VIO / Flash Pattern Selection:
This feature allows the user to select from several available flash patterns.
The lighthead must be switched on for Scan-Lock™ to work.
TO CYCLE THROUGH ALL PATTERNS: Apply +VBAT to the WHT/VIO
wire for less than 1 second and release. To cycle backward through patterns
apply +VBAT to the WHT/VIO wire for over 1 second and release.
TO SET A PATTERN AS DEFAULT: Allow the pattern to run for more than 5
seconds. The lighthead will flicker slightly when the pattern locks in. This flicker may be difficult to see with some patterns. The lighthead will now display this pattern
when activated.
TO RESET TO THE FACTORY DEFAULT PATTERN: Turn off power. While applying +VBAT to the WHT/VIO wire, turn power on. This will reset the lighthead to it’s
factory default flash pattern.

IMPORTANT! It is the responsibility of the installation technician to make sure that the installation and operation of this product will not interfere with or
compromise the operation or efficiency of any vehicle equipment!

Advertising
This manual is related to the following products: