PEAK-rms HOLD (ACA & ACV only)
Response: 65ms to 90%

Ohms
RANGE Accuracy

999.9

1.0% + 6d

Open Circuit Voltage : 0.4VDC typical

Audible Continuity Tester
Audible threshold: between 10

Ω and 300Ω.

Response time: 250

µs

ACA Current (Clamp-on)
RANGE Accuracy

1) 2)

50Hz / 60Hz
40.00A, 400.0A, 1000A

1.0% + 5d

45Hz ~500Hz
40.00A, 400.0A

2.0% + 5d

1000A

2.5% + 5d

500Hz ~ 3.1kHz
40.00A, 400.0A

2.5% + 5d

1000A

3.0% + 5d

ACA AutoVA

TM

Threshold: 1A AC (40Hz ~ 500Hz only) nominal

Crest Factor:

< 2.5 : 1 at full scale & < 5.0 : 1 at half scale for 40.00A & 400.0A ranges
< 1.4 : 1 at full scale & < 2.8 : 1 at half scale for 1000A range

1)

Induced error from adjacent current-carrying conductor: < 0.06A/A

2)

Specified accuracy is from 1% to 100% of range and for measurements made at the jaw

center. When the conductor is not positioned at the jaw center, position errors introduced
are:

A
(
A
(

dd 1% to specified accuracy for measurements made WITHIN jaw marking lines

away from jaw opening)

dd 4% to specified accuracy for measurements made BEYOND jaw marking lines

toward jaws opening)