Amprobe AM91RS Digital-Multimeter User Manual

Page 13

Advertising
background image

12

µµ

A, mA, and A Current functions

Default at DC. Press SELECT button momentarily to select AC. Press SELECT button

momentarily again to select AC + Hz. A will be selected automatically when the correct

input jack is plugged in.

Note:

When measuring a 3-phase system, special attention should be taken to the phase to

phase voltage which is significantly higher than the phase to earth voltage. To avoid

exceeding the voltage rating of the protection fuse(s) accidentally, always consider the

phase to phase voltage as the working voltage for the protection fuse(s).

RS232C PC computer interface capabilities

The instrument equips with an optical isolated interface port at the meter back for data

communication. PC interface kit (RS232C optical adapter cable + RS232C software

floppies) is required to connect the meter to the PC computer. The RS232C Data

Recording System software equips with a digital meter, an analog meter, a comparator

meter, and a Data Graphical recorder display. Refer to the README file in the interface

kit for further details.

Advertising