Amprobe AM91RS Digital-Multimeter User Manual

Page 23

Advertising
background image

22

6) SPECIFICATIONS

GENERAL SPECIFICATIONS

Display: 3-3/4 digits 4000 counts or 4-3/4 digits 40000 counts selectable (5 digits 99999 counts for Hz), and 4 digits 9999 counts dual display LCD

Polarity: Automatic

Update Rate:

3-3/4D Data: 5 per second nominal;

4-3/4D Data: 1.25 per second nominal;

43 Segments Bar graph: 128 per second max

Low Battery: The indicator appears when the battery voltage drops below approx. 5.8V

Operating Temperature: 32F to 122F (0

to 50

)

Storage Temperature: -4F to 140 (-20

to 60

), 80% R.H. (with battery removed)

Relative Humidity: 80% at 32F to 95 (0

to 35

), 70% at 95F to 122F (35

to 50

)

Temperature Coefficient: Nominal 0.15 x (specified accuracy)/

@ 23F - 65F or 83F - 122F (0

18

or 28

50

), or otherwise specified

Altitude: Operating below 2000m

Power Supply: Single Alkaline 9V battery NEDA1604A, JIS6AM6 or IEC6LF22

APO Timing: Idle for 4.5 minutes

APO Consumption: 20

µ

A typical

Sensing: True RMS conversion

Power Consumption: 12 mA typical

Weight: 390 gm; 500 gm with holster

Dimension: L186mm X W87mm X H35.5mm; L198mm X W97mm X H55mm with holster

Accessories: RS232 adapter cable, RS232 software floppies, Test leads (pair), holster, battery installed, and user's manual

Safety :

The meter meets the requirements for double insulation to IEC61010-1(1995), EN61010-1(1995), UL3111-1(6.1994), CSA C22.2 NO. 1010-1-92 to terminals:

V/R : Category IV 600V ac and dc, and Category III 1000V dc and 750V ac.

µ

A/mA : Category III 500V ac, and Category II 300V dc.

A : Category III 600V ac, and Category II 300V dc.

Transient protection : 8kV (1.2/50

µ

s surge)

E.M.C. : Meets EN55022(1994/A1; 1995/Class B) and EN50082-1(1992)

In an RF field of 3V/m:

Capacitance function is not specified

Other function ranges: Total Accuracy = Specified Accuracy + 30 digits

Performance above 3V/m is not specified

Advertising