Amprobe AM91RS Digital-Multimeter User Manual

Page 29

Advertising
background image

28

dBm

At 600

, -5.74dBm to 54.25dBm,

Accuracy :

±

0.25dB + 2d (@40Hz

20kHz)

Selectable reference impedance of 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200

Input Impedance : 10M

, 30pF nominal

Update Rate : 1.1 per second nominal

Overload protection : 780Vrms / 1000Vpeak

RECORD mode

Nominal Response for DC : 50ms to 80%, 100ms to 99%

Nominal Response for AC : 50ms to 80%, 100ms to 95%

Accuracy : Specified accuracy

±

10 digits for changes

200ms in duration for DC (

±

40 digits in AC)

Auto-ranging buffer : 1.5s (except Cx, & AC+DCV)

CREST mode

Accuracy : Specified accuracy

±

220 digits for changes

0.8ms in duration

SORT mode

Nominal sort rate : 0.2s (except Cx, & AC+DCV)

Accuracy : Specified accuracy

±

5 digits

Advertising