Amprobe AM91RS Digital-Multimeter User Manual
Page 29
Advertising
28
dBm
At 600
Ω
, -5.74dBm to 54.25dBm,
Accuracy :
±
0.25dB + 2d (@40Hz
20kHz)
Selectable reference impedance of 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200
Ω
Input Impedance : 10M
Ω
, 30pF nominal
Update Rate : 1.1 per second nominal
Overload protection : 780Vrms / 1000Vpeak
RECORD mode
Nominal Response for DC : 50ms to 80%, 100ms to 99%
Nominal Response for AC : 50ms to 80%, 100ms to 95%
Accuracy : Specified accuracy
±
10 digits for changes
200ms in duration for DC (
±
40 digits in AC)
Auto-ranging buffer : 1.5s (except Cx, & AC+DCV)
CREST mode
Accuracy : Specified accuracy
±
220 digits for changes
0.8ms in duration
SORT mode
Nominal sort rate : 0.2s (except Cx, & AC+DCV)
Accuracy : Specified accuracy
±
5 digits
Advertising