Amprobe AM91RS Digital-Multimeter User Manual

Page 28

Advertising
background image

27

Duty Cycle

RANGE

Accuracy

0.1%

99.9%

0.5d/kHz

2d

Input Frequency : 50Hz

250kHz; 5V Logic Family with + & - pulse width

2

µ

s

Update Rate : 1.2 per second nominal

Overload protection : 600VDC/VAC rms

Capacitance

RANGE

Accuracy*

4.000nF**

4.0% + 10d

40.00nF

3.0% + 5d

400.0nF

0.8% + 5d

4.000

µ

F

0.8% + 3d

40.00

µ

F

2.0% + 3d

400.0

µ

F

5.0% + 5d

4.000mF

5.0% + 5d

40.00mF

6.0% + 5d

*Accuracies with film capacitor or better

**Specified from 10% to 100% of range

Overload protection : 600VDC/VAC rms

Ohms

RANGE

Accuracy

40.00

0.2% + 6d

400.0

, 4.000k

, 40.00k

, 400.0k

0.15% + 2d

4.000M

0.3% + 2d

40.00M

1.5% + 5d

400.0nS

0.7% + 5d

Open Circuit Voltage :

1.3VDC (

3VDC for 40

& 400

ranges)

Temperature coefficient : 0.1 X (Specified accuracy)/

@ 23F - 65F or 83F - 122F (0

18

or 28

50

)

Overload protection : 600VDC/VAC rms

Diode Tester

Range

Accuracy

Test Current (Typical) Open Circuit Voltage

4.000V

2%+1d

0.8mA

3.5 VDC

Overload Protection : 600VDC/VAC rms

Audible Continuity Tester

Audible threshold : between 10

and 60

. Response time < 150

µ

s

Overload protection : 600VDC/VAC rms

Advertising