21

Fuse Replacement

When the voltage can not be measured (Vnow = 0V) after properly connecting
the Analyzer and the solar panel, please check the fuse.

If the fuse is damaged (burned), please replace a new fuse by following the
procedures:

1. Turn off the Analyzer and remove all the connecting wires and power

sources.

2. Unscrew the battery cover. Disconnect the lithium battery and remove

the lithium battery with cover.

3. Unscrew the (4pcs.) screws of the bottom cover. Remove the bottom

cover. Remove the power connector connecting the bottom cover and
the circuit board (J2).

4. Remove the damaged (burned) fuse.

5. Put in a new fuse of the same specifications (15A / 250V).

6. Connect the power connector. Replace and screw the bottom cover.

7. Replace the lithium battery with cover. Replace and screw the battery

cover.