www.lsi.com/channel/products

127

unit is ON or OFF, the Voltage and Current columns indicate whether the
voltage or current is under or over the required thresholds, and the Identify
column lists the Identify setting of the power supplies.

Example:

//localhost> /c0/e0 show pwrs

PowerSupply Status State Voltage Current Identify

--------------------------------------------------------------

pwrs0 OK on OK OK Off

pwrs1 OK on OK OK Off

/cx/ex show alarms

This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.

Note that in this command, “alarms” may be abbreviated to “alms” as in this
syntax usage: /cx/ex show alms.

This command reports a summary of the alarms within the specified
enclosure. The Alarm column lists the alarm units' IDs, the Status column
lists the status of each alarm, the State column indicates if the alarm unit is
ON or OFF, and the Audibility column indicate whether the alarm is Muted or
Unmuted.

Example:

//localhost> /c0/e0 show alarms

Alarm Status State Audibility

---------------------------------------------------

alm0 OK OFF UNMUTE

/cx/e

x

show all

This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.

This command shows the current settings of all attributes for enclosure /cx/ex

/cx/e

x

/slot

x

show

This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.

This command shows information about the specified /slotx on the specified
enclosure /ex. The slot name is followed by its status. If a slot has been
inserted with a drive and no fault has been detected, the status is OK. If the
slot is empty the status will indicate NO-DEVICE. The port that is correlated
to the slot is indicated in the next column. If no device is found in the slot, that