Avago Technologies 3ware SAS 9750-4i User Manual
Page 40

Chapter 2. CLI Syntax Reference
32
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0
[name=string](9000 series)
[v0=n|vol=a:b:c:d](n=size of first volume in GB)
[rapidrecovery=all|rebuild|disable](9000 series SE/SA)
[storsave=<protect|balance|perform>]
(9000 series SX/SE/SA only)
/cx add rebuild=ddd:hh:duration (9000 series)
/cx add verify=ddd:hh:duration (9000 series)
/cx add selftest=ddd:hh (9000 series)
/cx set dpmstat=on|off (9000 series SX/SE/SA only)
/cx del rebuild=slot_id (9000 series)
/cx del verify=slot_id (9000 series)
/cx del selftest=slot_id (9000 series)
/cx set ondegrade=cacheoff|follow (9500S only)
/cx set spinup=nn (9000 series)
/cx set stagger=nn (9000 series)
/cx set autocarve=on|off (9000 series SX/SE/SA only)
/cx set carvesize=[1024...32768] (9000 series SX/SE/SA only)
/cx set rebuild=enable|disable|1..5 (9000 series)
/cx set rebuildmode=<adaptive|lowlatency> (9000 series SE/SA
only)
/cx set rebuildrate=<1..5> (9000 series SE/SA only)
/cx set autorebuild=on|off (9000 series SX/SE/SA only)
/cx set autodetect=on|off disk=<p:-p>|all
/cx set verify=enable|disable|1..5 (9000 series)
/cx set verify=advanced|basic|1..5 (9000 series SE/SA only)
/cx set verifymode=<adaptive|lowlatency> (9000 series SE/SA
only)
/cx set verifyrate=<1..5> (9000 series SE/SA only)
/cx set verify=basic [pref=ddd:hh] (9000 series SE/SA only)
/cx set selftest=enable|disable [task=UDMA|SMART](9000
series)
/cx flush
/cx update fw=filename_with_path [force] (9000 series)
/cx commit (Windows only. Also known as shutdown)
/cx start mediascan (7000/8000 only)
/cx stop mediascan (7000/8000 only)
/cx rescan [noscan]