3. Wiring DC Power Inputs
The 6-contact terminal block connector on the rear panel of the MGSW-28240F is
used for two DC redundant power inputs. Please follow the steps below to insert
the power wire.
100~240V AC
50/60 Hz
ON
AC POWER
OFF
DC POWER
ON
OFF
Ring R.O.
Fault
FAN2
FAN1
PWR
DC 2
DC 1
DC Input Range:
36V~60V
Fault
GND
GND
DO 1
DO 0
DI 1
DI 0
DC 2
DC 1
1
Insert positive / negative DC power wires into contacts 1 and 2 for DC POWER 1,
or 5 and 6 for DC POWER 2.
1. Tighten the wire-clamp screws for preventing the wires from loosening.
1
2
3
4
5
6
DC 1
Fault Alarm
DC 2
+
-
+
-
Note
The wire gauge for the terminal block should be in the range of 12
~ 24 AWG.
The DC Input range is from 36V to 60V DC.