3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates a DC inlet power
socket and consists of one terminal block connector within 6 contacts. It accepts
input power of 48V DC. Please follow the steps below to insert the power wire.
1. Insert positive / negative DC power wires into contacts 1 and 2 for POWER 1, or
5 and 6 for POWER 2.
IGS-10020PT / IGS-10020HPT Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1
2
3
4
5
6
Power 1
Power 2
+
-
+
-
Note
The wire gauge for the terminal block should be in the range from
12 to 24 AWG.