3. Wiring the Power Inputs

The Upper Panel of the Industrial Managed Switch indicates a DC inlet power
socket and consist one terminal block connector within 6-contacts. It accepts input
power 48V DC. Please follow the steps below to insert the power wire.

1. Insert positive / negative DC power wires into the contacts 1 and 2 for POWER

1, or 5 and 6 for POWER 2.

IGS-10020HPT Upper Panel

2. Tighten the wire-clamp screws for preventing the wires from loosing.

1

2

3

4

5

6

Power 1

Power 2

+

-

+

-

Note

The wire gauge for the terminal block should be in the range
between 12 ~ 24 AWG.