5
3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates a DC inlet power
socket and consist one terminal block connector within 6-contacts. It accepts input
power 48V DC. Please follow the steps below to insert the power wire.
1. Insert positive / negative DC power wires into the contacts 1 and 2 for POWER
1, or 5 and 6 for POWER 2.
IGS-10020HPT Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loosing.
1
2
3
4
5
6
Power 1
Power 2
+
-
+
-
Note
The wire gauge for the terminal block should be in the range
between 12 ~ 24 AWG.