Regulation
Compliance

FCC Part 15 Class A, CE

Environment

Temperature

Operating: -40~75 degrees C
Storage: -40~75 degrees C

Humidity

Operating: 5~95% (Non-condensing)
Storage: 5~95% (Non-condensing)

Cable

Coaxial

RG-6/U cable (Recommended)
max. 500 m with PoE+ (1,640 ft.)
max. 700 m with PoE (2,297 ft.)
max. 1200 m without PoE (3,937 ft.)

* The actual data rate will vary on the quality of the copper wire and

environment factors.

Caution

As the VC-203PT is power over coaxial, it only can work
with PLANET VC-203PR or VC-205PR. If connects with
Non-PoE coax-LAN equipments, it might cause the equip-
ment to damage.

Warning:

This side of connector

contains electric power

. Please be

careful before plugging into

the device

.

Pleas

e be r

emin

ded th

at the

cable

con

Do Not Touch

the Center Pin

Please take care of the conditions of the resistance value of cables as
follows.

Coaxial Cable Type

RG-59/U

Less than 30Ω/1000 ft.

RG-6/U

Less than 12Ω/1000 ft

Because there are various resistance values in the category of RG-59/U
or RG-6/U cable.