2 physical details – PLANET ICA-525 User Manual

Page 9

Advertising
background image

2.2 Physical Details

Identification of ICA-525 cables

Line In

1. RJ45 LAN socket: Connect to PC or Hub/Switch. For connect to 10Base-T Ethernet or

100Base-TX Fast Ethernet cabling. This Ethernet port built N-Way protocol can detect or
negotiate the transmission speed of the network automatically. Please use Category 5
“straight through” cable to connect the ICA-525 to a 100Mbps Fast Ethernet network switch or
hub.

NOTE: In case you need to connect the device to PC or notebook directly, you should use

cross over cable instead.

2. RS-485

&

DI/DO:

Connect RS-485 to external scanner and

connect to sensor in and alarm out devices.

Inside the TEL box:

Name Function
12VDC

DC 12V output (50mA maximum)

GND GND
D+

RS485 data +

D-

RS485 data -

DI Digital

signal

input

DO Digital

signal

output

NOTE: The RS-485 of ICA-525 is master that can control external scanner.

3. Local Video output (BNC port): The Network Camera also provides composite video output.

User can use BNC video cable to connect the Network Camera with a TV monitor or VCR.

4. DC-in Jack: The input power is 12VDC. Note that supply the power to the Network Camera

with standard power adapter included in package. Otherwise, the improper power adapter
may damage the unit and result in danger.

5. Line in (audio in): Connect an audio input source to the ICA-525.

RJ-45 LAN

Video Out

RS-485 & DI/DO
(Connect to the
bundled TEL box)

Line Out

12V DC In

8

Advertising