5. COM/GPIO:

The 7 pin terminal block includes 2 input ports and 1 output ports.

Terminal block for I/O connectors:

Name

Pin

Function

COM

1

Signal output

Relay-ON

2

Signal output relay

GND

3

Ground

DI1

4

Signal Input 1

DI2

5

Signal Input 2

12V

6

DC 12V

GND

7

Ground

6. Power Jack:

The input power is DC 12V.

Note

1. Only use the power adapter supplied with IP Camera otherwise,

the product may be damaged.

2. The power adapter is unnecessary when IP Camera is connected

to a IEEE 802.3af PoE switch. Otherwise, the product may be
damaged when IP Camera is connected to a PoE switch and
power adapter simultaneously.

7. LAN Socket:

The LAN socket is a RJ-45 connector for connections to 10/100Base-TX Fast
Ethernet cabling can detect or negotiate the transmission speed of the network
automatically. Please use CAT-5 or above cable to connect the IP Camera to a
100Mbps Fast Ethernet network switch or hub.

8. Reset Hole:

This button is hidden in the pinhole. Please refer to the user’s manual for more
information.

9. SD Card Slot:

The IP Camera has built-in an SD card slot accepts SD / SDHC memory card for
image / video event recording.