Setting Up Your Development Environment

MVI-ADMNET ♦ 'C' Programmable

Developer's Guide

'C' Programmable Application Development Module with Ethernet

Page 44 of 122

ProSoft Technology, Inc.

February 20, 2013

3.6.2 Connecting to the Module

To connect to the module’s Configuration/Debug port:
1

Connect your computer to the module’s port using a null modem cable.

2 Start the communication program on your computer and configure the

communication parameters with the following settings:

Baud Rate

19200

Parity

None

Data Bits

8

Stop Bits

1

Software Handshaking

None

3 Open the connection. Send the necessary command to terminate the

module’s program.

If there is no response from the module, follow these steps:

1 Verify that the null modem cable is connected properly between your

computer’s serial port and the module. A regular serial cable will not work.

2 Verify that your communication software is using the correct settings for baud

rate, parity and handshaking.

3 On computers with more than one serial port, verify that your communication

program is connected to the same port that is connected to the module.

4 If you are still not able to establish a connection, you can contact ProSoft

Technology Technical Support for further assistance.