ProSoft Technology MVI56-BAS User Manual
Page 162

BASIC CALLs Syntax
MVI56-BAS ♦ ControlLogix Platform
User Manual
BASIC Module (DB/BAS Compatible)
Page 162 of 234
ProSoft Technology, Inc.
December 13, 2011
CALL 85: Transfer MVI56-BAS Output Buffer to DH-485 Interface File
CALL 85 transfers up to 40 words of data from the BASIC output buffer to the
DH-485 CIF file.
Syntax:
PUSH [A]
PUSH [B]
CALL 85
POP [S]
Where:
A = word offset in DH-485 interface file
B = number of words to be transferred
S = CALL status
Code
Description
0
Successful
1
Illegal offset
2
Illegal number of words
Example:
.
.
.
100 GOSUB 1020
.
.
.
1000 REM This routine copies the BASIC Output Buffer to the
1010 REM CIF
1020 PUSH 0,32: CALL 85: POP STATUS
1030 IF(STATUS<>0) THEN PRINT "Transfer error code =",STATUS
1040 RETURN
.
.
.