Reference

MVI71-GEC ♦ PLC 5 Platform

User Manual

Generic ASCII Ethernet Communication Module

Page 54 of 86

ProSoft Technology, Inc.

May 11, 2011

Object in GSCInStat

Block
Offset
Start

Description

Server[3].Timeout

27

This status value contains the total number of times a

connection timeout occurred on the socket.

Server[3].CfgErrWord

28

This bit mapped word defines the configuration errors for the

server.

Server[4].Enabled

29

This flag defines if the server is utilized. A value of 0
indicates the server is not used. Any other value indicates

the server is used.

Server[4].State

30

This flag defines the current state of the server.

Server[4].IP

31

This double-word value contains the IP address of the client

connected to the server.

Server[4].Port

33

This word value contains the port address for the client

connected to the server.

Server[4].Open

34

This status value contains the total number of times the

server performed an open operation.

Server[4].Established

35

This status value contains the total number of times a

connection was established on the socket.

Server[4].Closed

36

This status value contains the total number of times a close

operation was performed on the socket.

Server[4].RxCount

37

This status value contains the total number of messages

received by the server.

Server[4].RxOverflow

38

This status value contains the total number of messages

received that exceed the specified buffer size for the server.

Server[4].TxCount

39

This status value contains the total number of messages

transmitted by the server.

Server[4].TxOverflow

40

This status value contains the total number of transmit
messages that exceeded the specified maximum buffer size

for the server.

Server[4].Timeout

41

This status value contains the total number of times a

connection timeout occurred on the socket.

Server[4].CfgErrWord

42

This bit mapped word defines the configuration errors for the

server.

Reserved

43 to 62

This data area is reserved for future use.

Last Write Count

63

This word contains the number of characters written on

server from last BTR block.


If word 1 of the Input Image block is set to -3, the data for the first three clients is

passed to the processor. The format of this block is as follows:

Parameter

Block Offset
Start

Description

Seq Number

0

Sequence number for this block.

Server Index

1

For this status data block, this word is set to a value of -3.

PassCnt

2

Program cycle counter

Product

3

Product name as ASCII string

Rev

5

Revision level as ASCII string