Side-Connect Backplane Data Transfer
The side-connect interface is the simplest method to implement the module.

Minimal ladder logic is required for the interface because the driver handles data

movement between the module and the processor automatically. Additionally,

this interface is much faster than the block transfer interface. The data flow

associated with this interface is shown in the following diagram:

The value found in the SC_DATA.TXT file on the module determines the starting

file number for the side-connect interface. The following table lists the files

required for the side-connect interface:

File Number

Example

Size

Description

Cfg File

N10

250

Data transferred from the processor to the module

Cfg File+1

N11

250

Data transferred from the module to the processor

The first file is used by the module to read data placed in the file by the

processor. The second file places received data from the network into the

processor. It is very important that these files be defined to prevent the processor

from faulting.