Modbus TCP/IP Protocol Configuration

MNET ♦ ProLinx Gateway

Driver Manual

Modbus TCP/IP Interface Module

Page 34 of 78

ProSoft Technology, Inc.

September 1, 2010

2.7

Ethernet Configuration

Use this procedure to configure the Ethernet settings for your module. You must
assign an IP address, subnet mask and gateway address. After you complete
this step, you can connect to the module with an Ethernet cable.

1 Determine the network settings for your module, with the help of your network

administrator if necessary. You will need the following information:

o

IP address (fixed IP required) _____ . _____ . _____ . _____

o

Subnet mask

_____ . _____ . _____ . _____

o

Gateway address

_____ . _____ . _____ . _____

Note: The gateway address is optional, and is not required for networks that do not use a default

gateway.

2 Double-click the E

THERNET

C

ONFIGURATION

icon. This action opens the Edit

dialog box.

3 Edit the values for my_ip, netmask (subnet mask) and gateway (default

gateway).

4 When you are finished editing, click OK

to save your changes and return to

the ProSoft Configuration Builder window.