Controlling the monitor with a pc (rs-232c), Nrepeater control – Sharp PN-V602 User Manual

Page 35

Advertising
background image

E

35

Controlling the Monitor with a PC (RS-232C)

IDLK ........The parameter of this command sets the ID

number of the monitor. The monitor is subject to all

subsequent commands.

Example:

IDLK0002

Following commands are for the monitor

with ID number: 2.

WAIT

Searching for monitor with ID number:
2

OK 002

Found monitor with ID number: 2

VOLM0030

Sets volume of monitor with ID

number: 2 to 30.*

WAIT

Processing

OK 002

VOLM0020

Sets volume of monitor with ID

number: 2 to 20.*

WAIT
OK 002
IDLK0000

Canceling fixed ID number setting

WAIT

Canceling IDLK

OK 002

Cancelation complete

VOLM0010

OK 001

The volume of the monitor with ID number:

1 (the one directly connected to the PC) is

set to 10. (IDLK is canceled.)

* The IDLK command remains effective until it is

canceled, or power is shut off.

IDCK ........Provides screen display of the ID number currently

assigned to a monitor, and the ID number currently

set for IDLK (if any).

Example:

(After executing IDLK0002)

IDCK0000

(Parameter has no meaning.)

ID : 001 IDLK : 002

Returned response. The ID

number is also displayed on the

monitor screen.

IDCK000 +

Repeater control. (If a command

is used with repeater control, ID

designation using IDSL or IDLK

is canceled.)

WAIT
ID : 001 IDLK : 000
ID : 002 IDLK : 000
ID : 003 IDLK : 000
ID : 004 IDLK : 000

n

Repeater control

This system has a function to allow setting of multiple

monitors connected in a daisy chain using a single command.

This function is called repeater control. You can use Repeater

control function without assigning ID numbers.

[Example]

Set 1

Set 2

Set 3

Set 4

* If monitors are connected as shown above, you can

execute a command like “Set all monitors’ input settings to

PC D-SUB”.

Advertising