Maintenance and service – Enviro C-11212 User Manual

Page 12

Advertising
background image

12

Maintenance And Service

b) Insert a

5

/

32

” or 4 mm Allen wrench into the

hexagonal key-way of the screw (see Figure 12),

rotate it counter-clockwise until it is free and

extract it.

c) Check that the screw is clean and if necessary

remove dirt.

d) Flip the screw (refer to Figure 13).
e) Using the Allen wrench as shown in Figure 12,

rotate the screw clockwise until a torque of 9 inch

lbs. WARNING! Do not over tighten the screw.

It is recommended that you grip the wrench by

the short side.

f) Verify that if the conversion is from NG to LPG,

the screw must be re-assembled with the red o-

ring visible (refer to Figure 14). If the conversion

is from LPG to NG, the red o-ring of the screw

must be not visible.

Figure 13: Flip valve

screw.

g) Re-attach the black protection

cap that was removed in step a

(Figure 11).

8. Reinstall the burner, brick panels,

log set, embers, and glass door. Also

refer to S

ECONDARY

I

NSTALLATION

-

I

NSTALLING

L

OG

S

ET

AND

E

MBERS

. When

re-installing the burner, ensure that

the burner to pilot hood relationship

Figure 14: O-ring on valve screw.

is similar to what is shown in Figure 15. On some units you will need

to pay special attention when installing the burner that the venturi

adjustment rod is properly installed into the venturi adjustment piece

welded to the burner venturi tube

9. Reconnect the main gas line if it was disconnected and open the

shut-off valve at the gas line to the unit.

10. Use a small brush to apply a warm soapy water solution to all gas

connections (use half dish soap and half warm water). If a gas leak

is present, bubbling will occur. Gas leaks can be repaired by using

an approved pipe thread sealant or approved Teflon tape. NEVER

USE AN OPEN FLAME WHEN TESTING FOR LEAKS. Check the gas

Figure 12: Removing valve

screw.

pressure of the appliance, refer to I

NITIAL

I

NSTALLATION

- G

AS

L

INE

C

ONNECTION

and Table 5.

11. Reconnect the electrical power to the unit.
12. Light the pilot and check for proper flames (see Figure 4). Light the burner in both high and low

settings to verify proper burner ignition and operation and proper flame appearance. The amount

of air to the venturi may need to be adjusted using the rod under the firebox (refer to O

PERATING

I

NSTRUCTIONS

- A

DJUSTING

V

ENTURI

A

IR

S

ETTINGS

). Also refer to Figure 37 for a flame appearance

picture.

13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the

unit has been converted to a different fuel type.

Figure 15: Burner to pilot hood

relationship.

Advertising
This manual is related to the following products: