Turn off unit, Blower speed, Normal sounds during operation – Enviro C-11212 User Manual

Page 8: Adjusting venturi air settings, Operating instructions

Advertising
background image

8

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

T

URN

O

FF

U

NIT

:

Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. If

the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF,

for the first two to four hours. This will cure the paint, logs, gasket material, and other products used

in the manufacturing process. It is advised that a door or window be opened, as the unit will start to

smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF,

including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good

gas fireplace glass cleaner, available at your local Enviro dealer. See “D

OOR

R

EMOVAL

” and “C

LEANING

T

HE

G

LASS

” sections.

B

LOWER

S

PEED

:

The blower will come on only when the fireplace is up to temperature (approximately

20 minutes). Turning the fan control knob will change the speed of the fan. To turn

the blower off, turn the knob COUNTER-CLOCKWISE until it “clicks” off (Figure 6).
It is advisable not to operate the blower below

1

/

3

speed as it puts a strain on the

windings of the blower and running the blower at lower speeds could also cause

premature fan failure.

N

ORMAL

S

OUNDS

D

URING

O

PERATION

:

Table 2: Normal Sounds.

Component

Sound & Reason

Focus & Fascia

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

��

���

��

Figure 6: Fan control.

A

DJUSTING

V

ENTURI

A

IR

S

ETTINGS

:

There is one venturi adjustment.
Use this venturi adjustment lever, shown in Figure 7, to

achieve a proper and efficient flame.
Adjust lever until the flame pattern is similar to Figure

37. Suggested pull out distances are 1⁄2” (13 mm)

minimum for Natural Gas and 7⁄8” (22 mm) minimum

for Propane.

Pull out the venturi adjustment to increase primary air at the venturi tube.

Push in the venturi adjustment to decrease primary air at the venturi tube.

Figure 7: Adjusting the venturi air setting.

Advertising