Removing the brick panel, Secondary installation – Enviro C-11212 User Manual

Page 25

Advertising
background image

25

Secondary Installation

R

EMOVING

T

HE

B

RICK

P

ANEL

:

The brick panel set is fragile, handle with extreme care.

The brick panel set comes pre-installed. The centre and top panel are the only panels that need to be

removed if the complete gas and electrical tray assembly must be removed. The side panels may remain

installed unless they are to be replaced.
1. Turn the unit off and allow the

unit to cool completely.

2. Remove the fascia or louvers,

open the door, and remove the

log set.

3. Pull out the bottom of the

centre panel while pushing up

on the top panel.

4. With the center panel out, the

top panel will easily come out.

Just slide the top edge back out

of the top lip in the firebox.

If the side and front panels must

be removed, continue with steps

5, 6, 7, and 8.
5. Lift the front panel, located on

the firebox bottom, from one

end and remove the panel at

an angle through the fire box

opening.

6. Remove the log support tray by

lifting the back of the tray up

and pull it out from under the

lip. Take care not to knock the

pilot and the side brick panels.

7. Remove the two (2) T-20

screws holding the bottom of

the baffle (shown in Figure

39).

8. Pull the panels out of the lips

at the front of the firebox and

carefully remove the panel from

the unit (shown in Figure 40).

To re-install, follow the above

steps in reverse. Ensure that

the front and side panels are

pushed as far forward as they

can be before continuing with the

installation.

Figure 40: Brick Panel Installation.

Figure 39: Brick Panel Installation.

Figure 38: Brick Panel Installation.

Advertising