Codes and approvals – Enviro C-11212 User Manual

Page 4

Advertising
background image

DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from

outside the dwelling, through a specially designed vent pipe system.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.
BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L

vent. May also be vented through a conventional chimney using a chimney liner kit.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association

guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000

(610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or

codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude

rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by OMNI - Test Laboratories, Inc and found to comply with the established

VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (SIENNA BV/DV; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS-FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

4

Codes And Approvals

This ENVIRO SIENNA Fireplace:
• Has been certified for use with either natural or propane gases. (See rating

label.)

• Is not for use with solid fuels.

• Is approved for bedroom or bed sitting room. (IN CANADA: must be installed

with a listed wall thermostat. IN USA: see current ANSI Z223.1 for installation

instructions.)

• Installation must conform with local codes or, in the absence of local codes, with

the National Gas and Propane Installation Code, CSA B149.1 in Canada, or the

National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to an approved venting system and not connected to

a chimney flue serving a separate solid fuel-burning appliance.

• Is not approved for closet or recessed installations.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on

for the first time, it should be turned onto high without the fan on for the first 4

hours. This will cure the paint, logs, gasket material and other products used in

the manufacturing process. It is advisable to open a window or door, as the unit

will start to smoke and can irritate some people. After the unit has gone through

the first burn, turn the unit off including the pilot, let the unit get cold then remove

the glass door and clean it with a good gas fireplace glass cleaner, available at

your local ENVIRO dealer.

Advertising
This manual is related to the following products: