Initial installation, Clearances to combustibles – Enviro C-11212 User Manual

Page 13

Advertising
background image

Initial Installation

WARNING: Operation of this heater when not connected to a properly installed and maintained

venting system can result in carbon monoxide (CO) poisoning and possible death.

C

LEARANCES

TO

C

OMBUSTIBLES

:

Maintain sufficient clearances for operation, service and maintenance.
• A clearance of 25 1⁄2” (648 mm) minimum is required from the center of the unit to the sidewalls.

10" (254mm) Mantle

2" (51mm)

Mantle

39" (991 mm)

minimum to

bottom of unit

43" (1092 mm)

minimum to

bottom of unit

Figure 16: Mantle width and height.

• A 2” (51 mm) wide mantel can be mounted at a

minimum height of 39” (991 mm) from the bottom

of unit.

• A 10” (254 mm) wide mantel can be mounted at a

minimum height of 43” (1092 mm) from the bottom

of unit.

• If installed at floor level, a minimum 16” (406 mm)

non-combustible material must be installed in front

of the unit.

• If installed on a 12” (305 mm) wide hearth raised a

minimum height of 6” (152 mm), no floor protection

is required.

• Refer to Figure 17 for additional required floor

protection dimensions with different width hearths.

Sienna

0"

(0

m

m

)

5"

(1

27

m

m

)

6"

(1

52

m

m

)

7"

(1

78

m

m

)

8"

(2

03

m

m

)

9"

(2

29

m

m

)

10

"(

25

4m

m

)

11

"(

27

9m

m

)

12

"(

30

5m

m

)

13

"(

33

0m

m

)

14

"(

35

6m

m

)

15

"(

38

1m

m

)

16

"(

40

6m

m

)

Hearth Height

of 6" (152mm)

Non-combustible

floor protection required

in front of corresponding

hearth width

6"

(1

52

m

m

)

11

"(

27

9m

m

)

12

"(

30

5m

m

)

EXAMPLE: If the Sienna is raised

6" (152mm) and has 4" (102mm)

wide hearth in front of it then 12"

(305mm) of non-combustible

floor protection is require to

be installed in front of the

hearth.

Figure 17: Floor protection distance required.

13

Advertising
This manual is related to the following products: