Important Notice and Installation Guidelines

❖

DJI O3 Air Unit Installation Method and Cooling Effect

DJI O3 Air Unit is integrated with both the image transmission module and the camera module.

Compared with the last generation DJI Digital FPV System, the size of DJI O3 Air Unit is reduced by

40%, while the power consumption is increased by 40%. Restricted by its cooling condition, extra

ventilation and heat dissipation measures are necessary when installing the air unit.

Standby Time (from cold start):

Environment temperature 25° C (77° F): 8 mins

Environment temperature 35° C (95° F): 5 mins

When installing the DJI O3 Air Unit, make sure that the RX and TX pins are correctly connected

to the flight control board. The air unit can apply different temperature control strategies for the

standby and flight states.

[1]

[1] DJI O3 Air Unit has two sets of temperature control strategies for the standby state and the flight state:

In the standby state, the protection system will be activated to automatically shut down the air unit after overheating.
In the flight state, there will be a prompt alert after overheating and the video recording will end. At this time, the video

transmission will remain connected and the aircraft must return and land within 30 seconds. If the temperature of the
internal IC board continues to rise, the protection system will be activated to shut down the air unit automatically.

Installation Guidelines

Recommended installation practices that are effective for ventilation and heat dissipation:

It is recommended to mount the air unit in a position close to the propellers (distance between

the air unit module and the propellers within 10 mm) so that the downwash can be effectively

utilized.

Use a heat conductive material to connect the aircraft frame and the air unit module. This will

dissipate heat to the carbon plate and other metal components of the frame. Conducting the

heat will extend the operating time.

DO NOT install the air unit in an enclosed area.

The metal casing of the DJI O3 Air Unit will become hot after being powered on. The air unit

should not be installed in a position that is easily accessible.