Device Programming and Setup:

Installation

System Installer must adhere to Article 820-40 of the NEC

that provides guidelines for proper grounding and specifies

that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as

possible.

Unpacking and Inspection

Each unit is shipped factory tested. Ensure all items are removed from the container prior to discarding any packing material.
Thoroughly inspect the unit for shipping damage with particular attention to connectors and controls. If there is any sign of

damage to the unit or damaged or loose connectors contact your distributor immediately. Do not put the equipment into

service if there is any indication of defect or damage.

Hardware Installations and Connections

It is highly recommended that quality cables and connectors be used for all video and audio source connections.

The unit is designed to be rack mounted in a standard EIA19” rack.

The unit comes standard with HDMI and DIN inputs (Component and Composite video inputs). The DT-IPTV-QAM-

ASI-4HC encoder / modulator is intelligently designed to detect the video input from the video source.

HDMI

Connection:

Connect the HDMI cable(s) from the video source(s) into the HDMI input(s). Or, Connect the DIN Cable

to the back of the encoder as required using the DIN to DIN or DIN to breakout cable.

Repeat this step for each video source connection required.

Be sure the connections for each source are consistent with the unit’s inputs (IN1…IN4).

Use a quality

75Ω coaxial cable with “F” connectors from the unit’s

RF OUT jack

to the

distribution system

(combiner

or reverse splitter) or directly to a television.

Connect the included power cord to the unit’s

POWER

plug.

Connect the power cord to an appropriately rated AC power outlet.

Connecting to the GUI Interface:

Factory Default IP: 192.168.1.9

1.

Connect an Ethernet cable directly (

no Cross Over cable required

) to the Web Management Port on the rear panel

of the encoder or connect the Ethernet cable to an Ethernet switch. Connect an Ethernet Cable to your PC/Laptop.

2.

Modify your PC/Laptop IP address to 192.168.1.11.

3.

Enter ‘192.168.1.9’ into your web browser.

4.

Enter GUI and make required device changes.

5.

Save all changes as required, upload and reboot for changes to take effect.

6.

Verify parameters then end web session.