SECTION 4 − INSTALLATION

4-1. Specifications

50/60 Hz

Amperes Input at

Rated Load

Output 50/60 Hz

Rated

Output

Type of

Output

Plasma

Gas

Rated

Cutting

Capacity

Maximum

Open-Circuit

Voltage DC

208 V

230 V

KVA

KW

Output

Output

Gas

Capacity

Voltage DC

Single-

Phase

33

30

6.8

6.7

40 A @ 140

Volts DC,

50% Duty

Cycle

Direct

Current,

Straight

Polarity

(DCEN)

Air Or

Nitrogen

Only

0.5 in

(12.7 mm)

At 16 IPM

260

4-2. Specifications For Torch

Air-cooled torch for plasma arc cutting (PAC)

50% duty cycle

Safety interlock devices disable power source

Safety trigger guard

Cutting capacity: see Section 4-1

4-3. Duty Cycle And Overheating

Duty Cycle is percentage of 10

minutes that unit can cut at rated

load without overheating.
If unit overheats, output stops,

temperature status light

illuminates, and cooling fan runs.

Wait fifteen minutes for unit to cool

or temperature light to go off.

Reduce amperage or duty cycle

before cutting or gouging.
Y Exceeding duty cycle can

damage unit and void

warranty.

Overheating

sduty1 5/95 / Ref. 803 219

For Units Connected to a 208 Volt Circuit or a 230 Volt Circuit:

50% Duty Cycle At 40 amperes, 140 volts dc (typical cutting)

0

15

Minutes

A

OR

Reduce Duty Cycle

5 Minutes Cutting

5 Minutes Resting

4-4. Torch Dimensions And Weight

Ref. 801 397-A

3.5 lb (1.6 kg) With 25 ft (7.6 m) Cable

1 in (25 mm)

8-3/8 in

(213 mm)

1-3/8 in (35 mm)

Advertising