Hobart Welding Products AirForce 625 And ICE-40C Torch User Manual

Page 19

Advertising
background image

OM-926 Page 15

4-10. Wiring Optional 240 Volt Plug (119 172) For Connection To Bobcat, Trailblazer Or

Champion 10,000

Ref. 120 813-D / Ref. 803 222

1

Input And Grounding

Conductors

2

Plug Wired for 240 V, 2-Wire

Load

3

Neutral (Brass) Terminal And

Prong (Not Used)

4

Load 1 (Brass)Terminal And

Prong

5

Load 2 (Brass) Terminal And

Prong

6

Ground (Brass) Terminal And

Prong

7

Black And White Input

Conductors

8

Green Or Green/Yellow

Ground Conductor

Y Always connect green or

green/yellow wire to ground

terminal, never to a load

terminal. Connect black (L1)

and white (L2) wires to load

terminals.

Tools Needed:

7

Green Or

Green/Yellow

2

3

4

5

6

240V

8

3/16 in

8

7

6

5

4

3

Plug Front

View

Y Engine Control Switch must be set at “RUN”

position − not “RUN/IDLE”.

Y Set generator Fine Adjustment Control to 10

for maximum auxiliary power, if applicable.

1