OM-926 Page 23

6-2. Overload Protection: Status Lights & Checking Shield Cup Shutdown System

If certain problems occur, a status

light comes on, and output stops.
1

Pressure Light

Lights if gas/air pressure is below

40 PSI (276 kPa).
Turn power Off, and check for

proper gas/air pressure (see

Section 4-12).
A flashing Pressure light indicates

that gas/air system may be set too

low, faulty, leaking or has a flow

restriction (see Section 6-4).
2

Cup Light

Lights if shield cup is loose/off.
Turn Power On and loosen shield

cup. If shutdown system works

properly, Cup light comes on. If not,

turn power Off and have a factory

authorized service agent check

unit.
If system works properly, retighten

cup and reset power.
Turn power Off, and check shield

cup connection (see torch Owner’s

Manual). Power must be reset

whenever the cup shutdown is

activated.
A flashing Cup light indicates that

the torch consumables are stuck or

worn and should be inspected and/

or replaced (see Section 6-3).
Check shield cup shutdown system

once a week.
3

Temperature Light

Lights if power source overheats or

when ambient temperature is below

−20

°

C (−4

°

F) (see Section 4-3).

Fan-On-Demand
Cooling fan will operate during the

following conditions:

a

Unit is in an OVERTEMP

condition. TEMP indicator

light will illuminate and fan

will run until unit cools

down.

b

Unit gets hot during idle,

either from a change in

ambient air temperature or

after long periods of

cutting.

c

Unit is in cutting or postflow

mode.

Ref. 200 808 / Ref. 801 300-A

Checking Torch Shield Cup Shutdown System

Power must be reset whenever the cup shutdown system is activated.

Always turn Off power when changing or checking consumables.

1

2

3

Shield

Cup