Section 5 − operation, 1. controls, 2. cutting speed – Hobart Welding Products AirForce 625 And ICE-40C Torch User Manual

Page 21: 1. controls 5-2. cutting speed

Advertising
background image

OM-926 Page 17

SECTION 5 − OPERATION

1

Output Control

Use control to set cutting output.
Place control in Gas/Air Set position to safely

adjust gas/air pressure. Only gas/air circuit

is activated.
2

Status Lights (See Section 6-2)

3

Power Light

4

Power Switch

.

The fan will normally run for
approximately 5 seconds after power

switch is placed in the Off position.

5

Pressure Gauge

6

Pressure Adjustment Knob

.

At ambient temperatures below −55 C

(235 F), readjustment of gas/air

pressure regulator may be necessary

(see Section 4-12).

Use only clean, dry air with 90 to 150 psi

(620 to 1035 kPa) pressure. Prevent

moisture from entering air supply at

extreme cold temperatures.

Ref. 211 048

2

6

4

5

3

1

5-1. Controls

5-2. Cutting Speed

The cutting speed curve shows the

recommended maximum cutting

speed capabilities of the power

source and torch for mild steel of

various thickness.
The best cut quality is achieved by

cutting near the chart line. Cutting

below the line (too slow) will result

in excess dross. Cutting above the

line (too fast) will cause blowback

and lack of penetration.

0

50

100

150

200

250

300

350

400

16GA

(0.060)

1/8th

1/4th

3/8th

5/8th

Mild Steel Thickness(inches)

Cut

Speed

(in./min.)

Advertising