Replaced (see section 6-3 – Hobart Welding Products AirForce 625 And ICE-40C Torch User Manual

Page 28

Advertising
background image

OM-926 Page 24

6-3. Checking/Replacing Retaining Cup, Tip, And Electrode

Overtightening will strip threads. Do not overtighten retaining cup during

assembly. Do not cross-thread parts causing stripping. Use care during torch

assembly and parts replacement.

Inspect shield cup, tip, and electrode for wear before cutting or whenever cutting speed has been significantly

reduced. Do not operate torch without a tip or electrode in place. Be sure to use genuine replacement parts.

A good practice is to replace both the tip and electrode at the same time.

Turn Off power source before checking torch parts.

Make sure this area is clean of

any debris.

Make sure swirl ring is clean of any

debris and no holes are

obstructed.

New

Worn

New

Worn

5

1/32 in

(1 mm)

Pit

4

3

8

7

6

2

1

Turn Off power source.

1

Drag Shield

2

Retaining Cup

Remove retaining cup. Check retaining cup

for cracks, and replace if necessary.

3

Tip

4

Opening

Remove tip. Check tip, and replace if open-

ing is deformed or 50% oversize. If inside of

tip is not clean and bright, clean with steel

wool. Be sure to remove any pieces of steel

wool afterwards.
5

Electrode

Check electrode. If center has a pit more

than a 1/32 in (0.8 mm) deep, remove and

replace electrode.
6

Swirl Ring

Remove swirl ring. Check ring, and replace

if side holes are plugged.
7

O-Ring

Check O-rings on torch. If needed, coat with

thin film of silicone lubricant (part no.

169 231). Replace if damaged.
8

Plunger Area

Check this area for any debris or foreign

material. Clean out if necessary.
Carefully reassemble parts in reverse order.

Ref. 803 224